A 20 GPM well pump needs to deliver 4.54 m³/h if your specification means 20 US gallons per minute, or 5.46 m³/h if it means 20 Imperial gallons per minute. It also needs to deliver that flow at the head your system requires. The difference between the two targets is about 913 liters every hour.
That difference can change which pump you buy. At 44 meters of total head, Liyuan lists its 100QJ4-60/12 at 5.0 m³/h. That point clears a minimum requirement of 20 US GPM but falls short of 20 Imperial GPM. Same pump, same head, different purchasing decision.
How Much Water Does a 20 GPM Well Pump Deliver?
| If the specification says… | Flow in L/min | Flow in m³/h | Time to deliver 1,000 L |
|---|---|---|---|
| 20 US GPM | 75.7 | 4.54 | About 13 min 13 sec |
| 20 Imperial GPM | 90.9 | 5.46 | About 11 min |
The fill times assume the pump maintains the stated flow and nobody draws water from the tank. The British Columbia Sprinkler Irrigation Manual lists US GPM and Imperial GPM separately. If an old well report, sprinkler schedule or tender says only “GPM,” check the document legend or ask the person who specified it. Don’t infer the unit from the buyer’s country.
If you know the tank volume and refill deadline, you can skip the gallon question altogether. For example, 1,000 liters in 12 minutes requires 83.3 L/min, or 5.0 m³/h, assuming no simultaneous draw. That is a clearer purchase requirement than “about 20 GPM.” If livestock or irrigation also draws from the tank during refill, add that demand to the required inflow.
Does “20 GPM” on a Pump Listing Mean 20 GPM at My Well?
No. Look for what the number describes: a series name, a maximum flow, or flow at a stated head. Only the last one tells you what the supplier expects at a particular operating condition.
For example, Van Isle Water sells a Franklin 1 HP, 20 GPM Series pump end. The listing identifies the unit as US GPM and gives a specific result: 19 GPM at an 80-foot depth to water and 50 psi discharge pressure. The “20 GPM” title identifies the series; the 19 GPM figure answers a buyer with those operating conditions. The listing also says less motor, an important distinction when comparing its price with a complete pump.
When two quotes both say “20 GPM,” ask each supplier to complete the same sentence: “This exact model delivers ___ US GPM at ___ feet of total dynamic head.” If one supplier gives maximum flow and the other gives flow at your required head, the quotes do not yet describe the same job.
Which Liyuan Pump Can Deliver 20 GPM at 44 Meters of Head?
Start with the paired flow and head values in the Liyuan 4-inch 100QJ performance table. Here is the row for one candidate:
| Liyuan model | Motor rating | Published point 1 | Published point 2 | Published point 3 |
|---|---|---|---|---|
| 100QJ4-60/12 | 1.5 HP / 1.1 kW | 3 m³/h at 70 m | 4 m³/h at 60 m | 5 m³/h at 44 m |
At 44 m, that last point equals 22.0 US GPM or 18.3 Imperial GPM. If your contract calls for at least 20 US GPM at 44 m, the published point clears the minimum. If it calls for at least 20 Imperial GPM at 44 m, this model misses it. If your process needs exactly 20 GPM, neither comparison establishes the actual flow: check where the pump and system curves meet and how you will control delivery.
For the higher requirement, the catalog gives you a useful next question. The 100QJ6-50/13 lists 6 m³/h at 50 m and 7 m³/h at 41 m. That makes it worth reviewing for the Imperial-flow duty, but not an automatic substitute: at 44 m it may deliver more water than the system needs or the well can sustain. Ask for the pump performance curve for the proposed version and supply frequency.
My Well Is 44 Meters Deep. Can I Use the 44-Meter Row?
Not on the basis of well depth alone. 44 m of total head is not the same as a 44 m borehole. For a well feeding sprinklers, start at the water level while pumping, measure up to the delivery point, then add the pressure the sprinklers need and the friction losses at the design flow.
For example, suppose the pumping water level sits 18 m below the wellhead and the sprinkler inlet sits 3 m above it. The sprinkler needs 2 bar, equivalent to about 20.4 m of water head. If the pipe and fittings lose 2.6 m at the intended flow, the pump faces 18 + 3 + 20.4 + 2.6 = 44 m TDH. The bottom of the borehole does not enter that sum.
If you change the target from 4.54 to 5.46 m³/h, recalculate the pipe loss. The same pipe carries more water, so the old 2.6 m allowance no longer describes the new duty. Liyuan’s well pump sizing article walks through that calculation if your installer has supplied water levels and pipe dimensions rather than a final TDH.
Will 20 GPM Run My Sprinklers Without Dropping House Pressure?
It depends on what runs together and where you need the pressure. Suppose your largest irrigation zone uses 14 US GPM and the house needs 6 US GPM at the same time. That gives you a 20 US GPM flow target. It does not tell you whether the farthest sprinkler still has enough pressure when someone turns on a shower.
Check the nozzle specification at its required operating pressure, then ask the installer for the pressure available at that sprinkler while the zone and the house are drawing water. A bucket test at an unrestricted outlet tells you how quickly water leaves that outlet. It does not prove the system can supply the same flow through the sprinklers at their required pressure. If the house loses pressure only when one zone starts, the well pump and sprinkler system article is a better next step than immediately ordering a larger motor.
What If My Well Test Shows Only 12 US GPM?
A 20 GPM pump does not turn a 12 GPM well into a continuous 20 GPM water source. If a pumping test supports 12 US GPM over the required period and the site needs 20 US GPM for 30 minutes, the shortfall is 8 × 30 = 240 US gallons, or about 908 liters. That figure is the usable water deficit for this example, not a finished tank size.
You now have two purchasing options worth pricing: split the irrigation zone to reduce peak demand, or fill storage at a rate the well can sustain and use a separate pump for peak delivery. For the storage option, verify that the well has enough time to refill the tank before the next peak. Liyuan’s low-yield well pump and storage article explains when those two pumps need different flow ratings.
What Should I Write on a 20 GPM Well Pump Quote Request?
Give each supplier the same flow unit, head and scope of supply. For the US-gallon example above, you can send this:
Please quote a complete submersible well pump and motor for at least 20 US GPM (4.54 m³/h) at 44 m total dynamic head. The well casing has an internal diameter of [___]. Our pumping test recorded [flow, pumping water level and test duration]. Site power is [voltage, phase and Hz]. Please mark the duty point on the curve for the exact model and state whether the price includes the motor and controls.
If the original requirement means Imperial gallons, replace the first line with “at least 20 Imperial GPM (5.46 m³/h) at [recalculated TDH].” If you do not know the head yet, send the water level, outlet elevation, required pressure and pipe details to Liyuan’s pump team. A supplier can work from those measurements. “20 GPM” on its own leaves the most important part of the quote open.
Email:Liyuan@liyuan-pump.com