5 Inch Submersible Pump: 130QJ8 Vs 130QJ12
A 5 inch submersible pump needs more than the correct well diameter: it must also deliver the required flow at the system’s total dynamic head. Liyuan’s 130QJ8 and 130QJ12 ranges offer different flow-and-head combinations, even when two models use motors with the same listed power.
For example, the 2026 catalog lists both the 130QJ8-300/40 and 130QJ12-200/29 with 11 kW motors. At 10 m³/h, their listed heads are 264 m and 227 m respectively. The motor rating alone therefore does not identify the right pump.
5 Inch Submersible Pump Specifications: Selected 130QJ Models
The following examples come from Liyuan’s 5- and 6-inch QJ pump catalog. The catalog expresses head in meters at the stated flow.
| Model | Listed Motor Power | Catalog Flow And Head Points |
|---|---|---|
| 130QJ8-160/20 | 5.5 kW | 6 m³/h at 171 m; 8 m³/h at 160 m; 10 m³/h at 132 m |
| 130QJ8-300/40 | 11 kW | 6 m³/h at 342 m; 8 m³/h at 300 m; 10 m³/h at 264 m |
| 130QJ12-100/15 | 5.5 kW | 10 m³/h at 112 m; 12 m³/h at 100 m; 14 m³/h at 91 m |
| 130QJ12-200/29 | 11 kW | 10 m³/h at 227 m; 12 m³/h at 200 m; 14 m³/h at 195 m |
These figures describe selected catalog points, not guaranteed site performance. The product page does not specify the test frequency or the full permitted flow range. Ask the supplier for the current curve and motor data for the exact quoted configuration.
Liyuan’s table lists a 50 mm (2-inch) outlet for these ranges. Confirm the exact connection and thread standard before ordering pipework.
What Is The Difference Between 130QJ8 And 130QJ12?
Liyuan’s 130QJ8 table includes performance points around 6, 8 and 10 m³/h. The 130QJ12 table includes points at 10, 12 and 14 m³/h. These points help buyers identify the relevant hydraulic family, but they do not establish the full permitted operating range.
A buyer who needs 8 m³/h at high head can start by reviewing the 130QJ8 curves. A buyer who needs 12 m³/h can start with the 130QJ12 curves. In either case, the actual head and approved operating range determine the shortlist.
Do not assume every 130QJ12 model produces more flow in your installation. The pump curve and the resistance of your system determine the actual operating point.
Can Two 11 kW Borehole Pumps Perform Differently?
Yes. In Liyuan’s catalog, these two 5 inch submersible pump models both list an 11 kW motor:
| Comparison At 10 m³/h | 130QJ8-300/40 | 130QJ12-200/29 |
|---|---|---|
| Listed head | 264 m | 227 m |
| Listed motor power | 11 kW | 11 kW |
Suppose a project requires 10 m³/h at 240 m total dynamic head. The 130QJ8-300/40 has a listed 264 m head at that flow, so it is a candidate for further review. The 130QJ12-200/29 lists 227 m at the same flow, below the example requirement.
A catalog point above the requirement does not complete the selection. The supplier must confirm the full curve, allowable flow range, motor loading and maximum system pressure.
What If The Buyer Needs 12 m³/h Instead?
Suppose another project requires 12 m³/h at 190 m total dynamic head. The 130QJ12-200/29 lists 200 m at 12 m³/h, so it is a candidate for curve-based review.
The selected 130QJ8 catalog points in the table above do not show its head at 12 m³/h. Ask the supplier for the complete approved curve; do not guess its performance by extending the table.
These are separate, hypothetical projects—not field tests. Each requires its own well and system data.
Grundfos explains that the operating point depends on where the pump curve and system characteristics meet. A catalog point helps narrow the choice, but it does not independently establish the actual flow in a well.grundfos.com
Can A 5 Inch Submersible Pump Fit A 5-Inch Well?
A nominal 5-inch designation does not guarantee that the complete pump-and-motor assembly will fit every 5-inch casing.
Ask the supplier for the maximum outside diameter of the assembly, including cable protection and any projecting parts. Then compare it with the smallest actual internal diameter of the casing.
Also consider:
- Casing joints or internal weld beads.
- Liners and mineral buildup.
- Well deviation.
- Space for the cable and installation accessories.
- The clearance required to remove the pump later.
Never force an assembly into a restricted well. The installer needs a practical way to retrieve it for service.
Does A Deep Well Always Need A High-Head Pump?
No. Total well depth does not equal the vertical lift the pump must provide.
For selection, start with the pumping water level at the intended flow. Then add the relevant elevation, required outlet pressure and friction losses. Avoid counting the same elevation twice.
For example, a 300 m well might have a pumping water level substantially above its bottom. The correct pump depends on that operating water level and the delivery system—not the 300 m depth alone.
Use the total dynamic head calculation article when the system includes a distant tank, pressure equipment or a long discharge line.
Can The Well Supply The Required Flow?
The well must sustain the planned flow for the required pumping period. A pump that can theoretically deliver 12 m³/h cannot make an underperforming well supply that amount indefinitely.
Ask for pumping-test records showing flow, drawdown, duration and recovery. If the well yield is lower than demand, the project may need smaller irrigation zones, a longer pumping schedule or storage.
A storage tank can separate a lower well-pumping rate from short periods of higher use. It does not increase the well’s sustainable yield.
What Pressure Rating Does A High-Head Pump System Need?
Check more than the normal operating pressure. A high-head 5 inch submersible pump can expose different parts of the system to different pressures depending on elevation, water level and operating condition.
Have the system designer check:
- The pump’s maximum head and the highest expected static water level.
- Pressure at the relevant pipe, valve and fitting locations.
- Maximum pressure during stopping and starting, including possible surge.
- Pressure ratings for the riser, wellhead, check valves and discharge pipe.
For an idea of scale, 300 m of water head corresponds to approximately 29.4 bar of differential pressure. That conversion does not mean every point in the installation experiences 29.4 bar. Gauge location, elevation, water level and system operation matter.
Do not select pipework using the normal duty pressure alone. Ask the pump supplier and system designer to review maximum operating, shut-off and surge conditions.
Does The 2-Inch Outlet Determine The Entire Pipe Size?
No. The discharge connection tells the buyer how the pump connects; it does not automatically determine the most suitable diameter for every section of the pipeline.
A long or narrow pipe can create substantial friction loss. A larger downstream pipe may reduce that loss if the design supports it. Check the actual internal diameter, flow, pipe length, fittings, pressure rating and mechanical load.
The submersible pump pipe size article explains those checks in more detail.
What Should You Confirm About The Motor And Controls?
Request the exact motor nameplate and control requirements for the proposed 5 inch submersible pump. Confirm:
- Voltage, frequency and phase.
- Rated current and motor power.
- Cable length and suitable cable size.
- Starting method and overload protection.
- Dry-run protection and expected starts per hour.
- Motor cooling and minimum flow requirements.
- VFD compatibility, if the system uses variable speed.
The catalog points above list motor power, but they do not establish the voltage or control configuration for every quoted unit. Do not assume a control box fits because its kW or HP looks similar.
What Information Should A Buyer Send For A 130QJ Quote?
Send Liyuan Pump:
- Required flow and outlet pressure.
- Pumping water level at the intended flow, plus well-test details.
- Total well depth and proposed pump setting depth.
- Smallest actual casing internal diameter.
- Pipe material, internal diameter, length and major fittings.
- Supply voltage, frequency and phase.
- Water temperature, sand content and available water analysis.
- Intended daily operating hours and control method.
Ask for the exact pump and motor models, a current curve with the duty point marked, the complete assembly dimensions, the outlet details and the allowable operating range.
Frequently Asked Questions
Is A 5 Inch Submersible Pump The Same As A 5 Inch Motor?
Not necessarily. A complete pump assembly includes the hydraulic pump end and motor. Confirm the dimensions and compatibility of the quoted combination.
Does An 11 kW Pump Always Deliver The Same Flow?
No. Liyuan’s 130QJ8-300/40 and 130QJ12-200/29 both list 11 kW motors, but their catalog flow-and-head points differ.
Can I Select A Pump Using Maximum Head?
No. Maximum head normally describes the zero-flow end of the curve. Select the model using the required flow and the head needed at that flow.
Can A 130QJ Pump Fill A Tank Or Supply Irrigation?
It may serve either duty when its curve matches the system. Direct irrigation often requires outlet pressure in addition to lift and friction losses; an open tank has different requirements.
Does A Stainless-Looking Pump Body Confirm Every Internal Material?
No. Request the material list for the actual quoted model, especially if the water contains abrasive solids or corrosive substances.
Choose a 5 inch submersible pump by the required flow and head, then confirm well fit, sustainable yield, motor compatibility and maximum system pressure.
Email:Liyuan@liyuan-pump.com
WhatsApp:+86 181-2828-2767