8 Inch Submersible Pump: Can The 8SG95 Deliver Your Required Flow And Head?
An 8 inch submersible pump must be selected by flow and head together—not by its diameter designation. In Liyuan’s 2026 catalog, the 8SG95/8 is listed at 95 m³/h with 96 m head, but at 120 m³/h its listed head falls to 62 m. A higher flow requirement can therefore make the same pump unsuitable even though the requested flow appears in its performance table.
This page compares selected Liyuan 8SG95 stainless steel impeller models for buyers checking a new borehole installation or an increase in water demand.
8 Inch Submersible Pump Specifications: Selected 8SG95 Models
The following figures are transcribed from the Liyuan 2026 pump catalog, PDF page 18, printed page 15. Head values are expressed in meters; power is the catalog-listed motor rating.
| Model | Listed Motor Rating | Head At 95 m³/h | Head At 120 m³/h |
|---|---|---|---|
| 8SG95/8 | 37 kW | 96 m | 62 m |
| 8SG95/9 | 37 kW | 108 m | 68 m |
| 8SG95/10 | 45 kW | 120 m | 82 m |
| 8SG95/11 | 55 kW | 132 m | 90 m |
| 8SG95/12 | 55 kW | 144 m | 99 m |
These are catalog performance points, not a guarantee of site output. The table does not establish efficiency, electrical consumption, continuous operating limits or suitability at a particular supply frequency. Request the current complete performance curve for the quoted configuration.
For unit comparison, 95 m³/h is approximately 26.4 L/s, while 120 m³/h is approximately 33.3 L/s.
Can An 8SG95 Pump Supply 120 m³/h At 90 Meters Head?
For a requirement of 120 m³/h at 90 m total dynamic head, the catalog lists:
- 8SG95/10: 82 m head at 120 m³/h—below the stated requirement.
- 8SG95/11: 90 m head at 120 m³/h—matches the stated point, but leaves no allowance in this table for additional head.
- 8SG95/12: 99 m head at 120 m³/h—a candidate for further review, not an automatic selection.
This comparison assumes that 90 m is the total dynamic head already calculated at 120 m³/h. It must not be the head previously calculated at a lower flow.
Choosing the /12 solely because it has more head would be incomplete. Its actual operating flow, power requirement and control method must also be checked. Extra available head does not simply disappear.
As explained in KSB’s operating-point reference, actual operation is determined by the intersection of the pump curve and the system curve. Use the pump performance curve guide to identify the information needed for this check.
What Changes When Water Demand Rises From 95 To 120 m³/h?
Consider an irrigation project that adds another group of sprinklers. The buyer wants more water but still needs sufficient pressure at the field.
For the 8SG95/8, moving between the two listed flow points reduces available pump head from 96 m to 62 m—a difference of 34 m. Meanwhile, losses in the existing pipeline generally increase at the higher flow.
The selection can therefore become less favorable from both directions: the pump provides less head while the system requires more.
Before approving the expansion, recalculate:
- Pumping water level at the increased withdrawal rate.
- Friction losses through the riser, mainline, valves and filtration equipment.
- Pressure required at the most demanding operating outlet.
The well must also sustain the increased abstraction rate. A larger pump cannot establish the well’s sustainable yield.
If the existing pipe is being retained, the submersible pump pipe size guide explains why actual internal diameter and pressure rating require separate checks.
Why Do Two 37 kW Borehole Pumps Have Different Head?
The 8SG95/8 and 8SG95/9 both have a listed motor rating of 37 kW. However, at 95 m³/h, their listed heads are 96 m and 108 m respectively.
A quotation stating only “8-inch, 37 kW deep well pump” does not identify which hydraulic performance is being offered.
Specify the complete model and the required duty point. Also distinguish motor rating from operating electrical input: the catalog’s kW column alone cannot establish energy consumption or pumping cost.
Does An 8 Inch Submersible Pump Fit An 8-Inch Well?
The product designation alone does not confirm installation clearance. Compare the smallest actual casing internal diameter with the maximum outside dimensions of the assembled pump, motor and cable protection.
Ask for an assembly drawing before approving installation. Well deviation, casing restrictions and the space required for removal also matter.
The catalog’s pump-body dimensions should not be treated as complete pump-and-motor dimensions. Similarly, “8 inch” is not the discharge connection size. Confirm the exact outlet connection on the quotation and drawing.
What Does “Stainless Steel Impeller” Confirm?
The catalog identifies this range as “SG-SS impeller.” That description should not be expanded into a claim that every wetted component is stainless steel, that all parts are 316 grade, or that the assembly has a particular drinking-water approval.
For corrosive or abrasive water, request the material specification for the impellers, diffusers, shaft and housing, together with applicable water-quality limits. Provide water analysis rather than asking only whether the pump is “corrosion resistant.”
Request An 8SG95 Selection For Your Actual Duty
Send Liyuan Pump the following details:
- Required flow and total dynamic head at that flow.
- Pumping water level, well yield and smallest casing internal diameter.
- Pipe dimensions, length, outlet pressure and operating zones.
- Voltage, frequency, phase and proposed control method.
- Water analysis, temperature and expected daily operating hours.
Request a quotation identifying the full model, a duty point marked on the current curve, motor details, assembly dimensions and confirmed discharge connection.
The key decision is not whether an 8 inch submersible pump can reach 120 m³/h. It is whether the quoted model can deliver 120 m³/h at your required head, within its approved operating range.
Email:Liyuan@liyuan-pump.com
WhatsApp:+86 181-2828-2767