100QJ Submersible Pump: Models, Flow And Head
A Liyuan 100QJ submersible pump should be selected by the flow it delivers at your required total head, not by horsepower alone. In Liyuan’s catalogue, two 2 HP models have very different listed points: 100QJ2-140/27 provides 2 m³/h at 140 m, while 100QJ10-33/7 provides 10 m³/h at 33 m.
The 100QJ is a 4-inch borehole-pump range. This page compares actual catalogue entries and explains what to confirm before ordering a pump end, motor or complete assembly.
Compare 100QJ Submersible Pump Models At 2 HP
The following models all have a catalogue motor-power listing of 2 HP / 1.5 kW. Each flow and head pair comes from the same model row; these are not maximum-flow and maximum-head figures combined into an operating point.
| Liyuan Model | Listed Flow | Head At That Flow | Catalogue Outlet Size |
|---|---|---|---|
| 100QJ2-140/27 | 2 m³/h | 140 m | 1.5 inch |
| 100QJ3-93/18 | 3 m³/h | 93 m | 1.5 inch |
| 100QJ4-80/16 | 4 m³/h | 80 m | 1.5 inch |
| 100QJ6-50/13 | 6 m³/h | 50 m | 1.5 inch |
| 100QJ8-36/8 | 8 m³/h | 36 m | 2 inch |
| 100QJ10-33/7 | 10 m³/h | 33 m | 2 inch |
Source: Liyuan’s 2026 pump catalogue, PDF pages 7–8, printed pages 4–5. Outlet entries are nominal catalogue descriptions, not measured thread diameters or complete connection specifications.
Use these values for initial comparison. Obtain the current curve for the exact model and operating frequency before final selection; the table is not a verified 60 Hz performance chart or an installation-depth chart.
Which Model Fits A Higher-Flow Application?
Compare candidates at the same required flow, rather than choosing the largest number in a model name.
For example, the catalogue lists three points for 100QJ6-50/13:
- 4 m³/h at 67 m head.
- 6 m³/h at 50 m head.
- 7 m³/h at 41 m head.
The same pump does not deliver 67 m head at every flow. If demand rises from 6 to 7 m³/h, its listed available head falls from 50 to 41 m.
For an irrigation zone, establish how much water the operating outlets need together. For tank filling, establish the required refill rate. Then compare that flow with the head the installation requires and the well’s sustainable yield.
Example: A Requirement Of 6 m³/h At 50 m Head
This is an illustrative catalogue-screening exercise, not a customer installation or a final pump recommendation.
100QJ6-50/13 has a listed point of 6 m³/h at 50 m. It is therefore a candidate for further curve and installation checks.
100QJ8-36/8 has a listed point of 6 m³/h at 41 m. Its separate MAX H entry is 53 m, but that does not mean it supplies 6 m³/h at 53 m. At the required flow, the listed head is below the example requirement.
The first candidate still needs verification across changing water levels, pressure settings and demand. A matching catalogue point alone does not establish acceptable motor loading or operation throughout the required range.
The submersible pump performance curve explains how to check the complete operating range.
Does A 140 m Head Mean A 140 m Deep Well?
No. Head describes the hydraulic duty, not simply the drilled depth or the depth at which the pump hangs.
For a typical open well supplying a pressurized outlet, the required total head includes the elevation rise from the pumping water level, the required outlet pressure expressed as head, and losses through the pipework and equipment.
Grundfos’ groundwater sizing explanation likewise bases selection on required flow and head, including the dynamic water level and system losses.
Consequently, “my well is 100 m deep” is insufficient to select a 100QJ submersible pump. Provide the water level during pumping at a stated flow, the delivery elevation, pressure requirement and pipe details.
Will A 100QJ Pump Fit My Existing Borehole?
The catalogue’s 4-inch overview lists a pump diameter of 96 mm. Treat that as catalogue dimensional information, not a guarantee that every assembled configuration will pass through every nominal 4-inch casing.
Confirm the smallest clear internal diameter along the installation path and the maximum outside dimensions of the proposed assembly, including its cable guard, outlet connection and any accessories.
Length also matters. The catalogue lists pump-body lengths of 926 mm for 100QJ2-140/27 and 579 mm for 100QJ10-33/7. Its footnote explicitly excludes the motor from these lengths and weights. Request complete assembled dimensions before arranging installation or shipping.
When replacing equipment, use the submersible pump replacement checklist to identify which existing components can remain.
What Outlet Connection Does The 100QJ Use?
The selected models above show either a 1.5-inch or 2-inch outlet. The catalogue also prints these as 40 mm and 50 mm descriptions. They should not be treated as exact dimensional conversions or measured thread diameters.
The listed size alone does not identify BSP, NPT, parallel or tapered threads, the connection gender, or the sealing arrangement. Request those details for the exact discharge-head configuration and mating part.
Swagelok’s thread and end-connection identification reference separates thread identification from the complete connection geometry. That distinction is useful when retaining an old adapter or ordering a conversion fitting.
The outlet also does not determine the correct diameter for the entire riser and delivery pipe. Use the submersible pump pipe-size explanation for friction, pressure and joint-loading checks.
Which Motor And Control Box Should You Specify?
Liyuan’s 4-inch catalogue overview lists single-phase 220–240 V / 50 Hz and three-phase 380–415 V / 50 Hz arrangements. Other voltages and 60 Hz are listed as options on request. Confirm availability and performance for the particular model; do not assume every listed hydraulic configuration has every motor option.
The separate control-box catalogue distinguishes these examples:
| Control Model | Listed Supply | Listed Motor-Power Range |
|---|---|---|
| C1-S2 | 220 V, single-phase, 50/60 Hz | 0.37–2.2 kW |
| C3-SP1 | 380 V, three-phase, 50/60 Hz | 0.75–4 kW |
Source: Liyuan control-box catalogue, PDF pages 3–4. The C3-SP1 row is distinct from the C3-SP2 row for 5.5–7.5 kW.
These ranges help identify a control family; they do not approve an exact pump-and-control combination. Confirm motor current, starting arrangement, capacitor requirements where applicable, protection settings and the installation environment. A 50/60 Hz control-box label does not establish identical pump performance at both frequencies.
The electric control-box selection page explains the information needed for that comparison. Electrical selection and installation should be completed by qualified personnel using the exact equipment instructions.
Request A Model-Specific 100QJ Submersible Pump Quote
Send the following information so the quotation can identify a complete configuration rather than just “a 2 HP pump”:
- Required flow and total dynamic head, or the site information needed to calculate them.
- Pumping water level, sustainable well yield and smallest clear casing diameter.
- Supply voltage, frequency and phase.
- Pipe and existing adapter details, including the full connection specification where known.
- Water temperature, sand information and relevant water-analysis results.
- Whether you need the pump end only or a complete assembly, and which cables, controls and accessories must be included.
Ask the quotation to identify the full pump model, motor, frequency-specific curve, assembled dimensions, outlet connection and control-box configuration. For water conditions outside the standard selection, request written suitability confirmation instead of assuming that every catalogue option applies.
For a Liyuan submersible pump enquiry, include the complete 100QJ model if you already have one. The useful comparison is the required flow at the required head, with compatible mechanical and electrical connections—not horsepower or maximum head alone.
Email:Liyuan@liyuan-pump.com