150QJ Submersible Pump: Which Model Delivers 25 m³/h At Your Required Head?
A 150QJ submersible pump must deliver the required flow at the system’s total dynamic head. For example, Liyuan’s 2026 catalog lists the 150QJ25-70/12 at 25 m³/h and 70 m head, while the 150QJ25-88/15 provides a listed 25 m³/h at 88 m head.
Both belong to the 150QJ25 range, but they do not serve the same pressure requirement. Before ordering, calculate the duty point, check the well yield and ask for the current curve for the exact configuration.
150QJ Submersible Pump Specifications: 25 m³/h Models
The table below uses selected points from Liyuan’s 2026 pump catalog, PDF page 13, printed page 10. Head values describe the catalog pump output at each stated flow.
| Liyuan Model | Listed Motor Power | Head At 20 m³/h | Head At 25 m³/h | Head At 30 m³/h |
|---|---|---|---|---|
| 150QJ25-40/7 | 4 kW | 46 m | 40 m | 28 m |
| 150QJ25-50/9 | 5.5 kW | 60 m | 50 m | 35 m |
| 150QJ25-70/12 | 7.5 kW | 80 m | 70 m | 50 m |
| 150QJ25-88/15 | 9.2 kW | 100 m | 88 m | 65 m |
| 150QJ25-105/18 | 11 kW | 120 m | 105 m | 70 m |
These values are catalog points, not a guarantee of performance in a particular well. The page does not specify the test frequency or the complete permitted flow range. Ask for the current pump curve and motor data for your supply before making a final selection.
The Liyuan manufacturer listing also shows these selected 150QJ25 figures. Older catalog versions contain differences at some flow points, so confirm the current data sheet when comparing quotations.
Can A 150QJ25 Pump Deliver 25 m³/h At 80 Meters Head?
According to the 2026 catalog, the 150QJ25-70/12 provides 70 m head at 25 m³/h. That falls below an example requirement of 25 m³/h at 80 m total dynamic head.
The 150QJ25-88/15 provides a listed 88 m head at 25 m³/h. It is therefore a candidate for further evaluation, not a final selection. The supplier should check the actual system curve, operating range, motor loading and maximum pressure.
The example assumes that 80 m already includes the pumping water level, elevation, required outlet pressure and pipe losses at 25 m³/h. It does not describe a tested installation.
How Do You Calculate The Head For A 150QJ Irrigation Pump?
For a preliminary irrigation calculation, combine:
- Vertical lift from the pumping water level to the selected reference elevation.
- Additional elevation to the irrigation outlet, if not already included.
- Pressure required at that outlet.
- Pipe, valve, filter and fitting losses at the required flow.
Avoid counting the same elevation twice. The total dynamic head calculation guide explains the components in more detail.
Example: Irrigation At 25 m³/h
Assume an irrigation system needs:
| Design Item | Example Value |
|---|---|
| Pumping water level below ground | 32 m |
| Outlet elevation above ground | 5 m |
| Required pressure at outlet | 3 bar |
| Pipe and equipment losses at 25 m³/h | 10 m |
For clean water, 3 bar is approximately 30.6 m of pressure head.
Total dynamic head = 32 + 5 + 30.6 + 10 = 77.6 m
The preliminary duty point is therefore 25 m³/h at approximately 78 m TDH.
The 2026 table lists 70 m for the 150QJ25-70/12 and 88 m for the 150QJ25-88/15 at that flow. On this simplified comparison, the latter is the candidate to review with the supplier.
This calculation uses assumed conditions. A real project needs measured water levels, actual pipe dimensions, sprinkler requirements and current manufacturer curves. It also needs a check at other expected operating conditions.
Why Is Pumping Water Level More Useful Than Total Well Depth?
Total well depth tells the installer about the physical well, but it does not by itself tell the pump how far it must lift water.
For pump selection, measure the water level while the well pumps at the intended flow. A well may be 120 m deep while the pumping water level is 32 m below ground. If discharge reaches ground level, the preliminary vertical lift starts from the pumping water level—not automatically from 120 m.
Pump setting depth still matters for submergence, installation clearance and motor cooling. It is simply a different measurement from pumping lift.
If water levels fall seasonally, ask the supplier to check the pump at the lowest expected pumping level as well as normal conditions.
What Happens If Irrigation Demand Rises To 30 m³/h?
The required head and the pump’s available head may both change when flow increases.
For example, Liyuan’s 2026 catalog lists the 150QJ25-88/15 at:
- 88 m head at 25 m³/h.
- 65 m head at 30 m³/h.
That is a 23 m reduction between the two listed flow points. At the same time, friction losses in a given pipe system generally increase with flow.
Do not assume the 25 m³/h selection will supply 30 m³/h at the same outlet pressure. Recalculate the system head at 30 m³/h, confirm the well can sustain the higher flow, and compare the result with the complete pump curve.
Grundfos explains pump curves as the relationship between flow and head. The curve must be considered together with the system characteristics; a single catalog number does not establish the field operating point.grundfos.com
If the existing pipeline limits the new demand, check its actual internal diameter, length and fittings. The submersible pump pipe size article covers hydraulic and pressure-rating checks.
Can The 150QJ Pump Fill A Tank And Supply Sprinklers?
It may, but first decide whether the two duties happen at different times or simultaneously.
Filling An Open Storage Tank
An open tank normally needs the pump to overcome the pumping lift, tank elevation and friction losses. It does not need the same outlet pressure as a sprinkler operating at 3 bar.
Confirm the tank inlet arrangement and the expected water level in the tank. A separate booster pump may supply pressure to sprinklers later, depending on the system design.
Supplying Sprinklers Directly
For direct irrigation, add the sprinkler’s required operating pressure and all relevant filter and pipe losses. Check the most demanding irrigation zone, not merely the average daily water volume.
Filling The Tank And Irrigating Together
If both branches operate at once, calculate the combined flow and the pressure each branch needs. The actual flows depend on the branch controls and hydraulic resistance; simply adding two nameplate flows does not prove the pump will deliver both.
Provide the supplier with a layout showing valves, pipe sizes, the tank and sprinkler zones. Ask the supplier to check both simultaneous and separate operating conditions.
Does A 150QJ Submersible Pump Fit Every 6-Inch Well?
No. The 150QJ designation does not prove that the complete pump and motor will pass through every nominal 6-inch casing.
Ask for the maximum assembly outside diameter, including cable protection and any fittings. Compare it with the smallest actual casing internal diameter, not just the nominal well size.
Casing joints, liners, mineral buildup and deviation can reduce the usable clearance. Also check whether installers can lower and later retrieve the assembly without forcing it.
For the 150QJ25 rows, Liyuan’s 2026 catalog lists a 65 mm, 2.5-inch outlet. Confirm the actual connection and thread standard for the quoted unit before ordering adapters or pipe.
What Does A Model Such As 150QJ25-70/12 Tell The Buyer?
In Liyuan’s catalog, 150QJ25-70/12 identifies a particular model with a listed duty point of 25 m³/h at 70 m head and a listed motor rating of 7.5 kW.
The model number helps identify a configuration, but it does not replace the performance curve. It does not by itself confirm the motor voltage, frequency, materials, maximum assembly diameter or suitability for a particular water source.
Different manufacturers may use similar QJ model formats but offer different configurations. Compare the full model, manufacturer, curve and motor data before accepting a replacement.
Can The Well Sustain 25 m³/h?
The pump can deliver the intended duty only if the well can supply enough water under the relevant operating conditions.
Review a pumping test that records flow, pumping duration, water-level drawdown and recovery. If the well cannot sustain 25 m³/h, possible system changes include smaller irrigation zones, longer operating time or storage—subject to the project’s requirements.
A storage tank can separate the slower well-pumping period from a short period of high irrigation demand. It does not increase the well’s sustainable yield.
What Should You Send For A 150QJ Pump Quote?
Send Liyuan Pump:
- Required flow and outlet pressure.
- Static and pumping water levels, plus test flow and duration.
- Total well depth, proposed pump setting depth and smallest casing internal diameter.
- Pipe material, internal diameter, lengths and major fittings.
- Whether the pump fills a tank, supplies irrigation directly, or does both.
- Supply voltage, frequency, phase and cable length.
- Water temperature, sand content and available water analysis.
Ask for the exact pump and motor models, a current curve with the duty point marked, complete assembly dimensions, outlet connection, power requirements and permitted operating range.
Frequently Asked Questions
Is The 150QJ25-70/12 A 25 m³/h Pump?
Liyuan’s 2026 catalog lists it at 25 m³/h and 70 m head. Actual flow depends on the system curve and the operating water level.
Can A 150QJ25-70/12 Produce 25 m³/h At 80 m Head?
The 2026 catalog lists 70 m at 25 m³/h, so that point falls below an 80 m requirement. Request a curve-based review of another configuration.
Is The Maximum Head The Same As The Head At 25 m³/h?
No. Maximum or shut-off head refers to the zero-flow end of the curve; the useful selection point combines the required flow with the head at that flow.
Can A 150QJ Pump Run On Solar Power?
A compatible solar-powered system may be possible, but the pump, motor, inverter, solar array and required daily water volume need a separate design. Do not connect an unspecified motor directly to solar panels.
Is A Higher-kW 150QJ Pump Always Better?
No. The selection must meet the required flow and head without exceeding well yield or system limits. More power alone does not establish a better match.
Choose a 150QJ submersible pump by its flow and head at the actual duty point, then verify the well, motor, dimensions and complete operating range.
Email:Liyuan@liyuan-pump.com